5 Operation / adjusting device settings - Set-up to commissioning Memo-Graph S
26 Endress+Hauser
Input principle:
1. Begin changing each parameter with “”.
2. Use “” or “” to leaf through values, symbols, selection lists.
3. If the parameter is set correctly, use “” to confirm.
!
Note!
Any settings that are displayed in grey can not be selected / can not be changed (only notes, or
option not available/not activated).
With the factory setting “0000” (delivery status), configuration is possible at any time. It can be
protected against unauthorised manipulation by entering a 4-digit release code. This has to be
entered when the settings are later changed, if the device settings are to be changed by key-
board.
Tip: make a note of your release code. Store it somewhere where unauthorised persons do not have
access to it.
The changed settings do not become effective until you return to normal operation by repea-
tedly pressing “ESC” and confirming with “”. Until this time, the device still works with the
previous data.
5.5 Set-up using PC
You can also put your Safety Data Manager into service and/or configure it via PC. The following
are available for this:
Front-mounted RS 232 operating interface (3.5 mm jack plug, stereo, protected behind the unit
cover; only available with die-cast front - not with stainless steel front)
Rear-mounted RS 232 or RS 485 system interfaces (depending on scope of delivery)
!
Note!
You can use the PC software ReadWin
®
2000, which is provided with the Safety Data Manager, to
put the device into service / configure it via PC. You can also download the software directly from
the internet under the followingg address:
www.endress.com/readwin
For further information on ReadWin
®
2000, refer to the operating manual of the software
(BA107R/09).
Installation of PC software:
1. Install the supplied PC software on your computer. The program's Operating Instructions can
be printed out after installation, if required.
2. Call up the program.
"
Caution!
3. Please make the plug connection first, then the connection to your PC. When removing the
connection, proceed in reverse order.
4. Now you can configure your device via PC. For this, please refer to the program's instruc-
tions/help.
Advantages of configuration via PC:
• The device data is saved in a database and can be accessed again at any time.
• Text entries can be carried out more quickly and efficiently by keyboard
• Measured values can also be read out, archived and displayed on the PC with this program.
"
Caution!
Configuration can only be carried out via one interface (RS 232 or RS 485) at a time.