4 Wiring Memo-Graph S
14 Endress+Hauser
Figure 3: Connections/terminal diagram
RxD/TxD(-)
RxD/TxD(+)
screen
Pin
8
5
3
2
housing
RS 232
GND
RxD
TxD
Ethernet
RS 232
RS 422/485
RS422 see
operation
manual
LNK
Rx
Tx
screen
RS 485
Option
Option
9
6
5
1
9
6
5
1
ATA - F l a s h M e m o r y C a r d
211
212
213
214
311
312
313
314
511
512
513
514
611
612
613
614
711
712
713
714
811
812
813
814
2
2
2
2
3
3
3
3
5
5
5
5
1
1
1
1
5
5
13
13
6
6
14
14
9
9
25
25
7
7
411
412
413
414
+/- 20 mV, +/- 50 mV, +/- 100 mV, +/- 200 mV
0...1 V, 0...10 V, +/- 1 V, +/- 2 V, +/- 5 V, +/- 10 V
J (Fe-CuNi):
L (Fe-CuNi):
R (Pt13Rh-Pt):
T (Cu-CuNi):
W3 (W3Re/W25Re):
W5 (W5Re/W26Re):
-210...+999,9 °C
-200...+900 °C
-50...+1800 °C
-270...+400 °C
0...+2315 °C
0...+2315 °C
B (Pt30Rh-Pt6Rh):
K (NiCr-Ni):
N (NiCrSi-NiSi):
S (Pt10Rh-Pt):
U (Cu-CuNi):
0...+1820 °C
-200...+1372 °C
-270...+1300 °C
0...+1800 °C
-200...+600 °C
Ch.1
Ch.2
Ch.3
Ch.4
Ch.5
Ch.6
Ch.7
Ch.8
111
112
113
114
max. 230 V / 3 A
+
12..24 V
DC
60 mA
_
Digital in (DI)
Digital out
(OC)
Rel.1
Rel.3
Rel.4
Rel.5
91
9191
91
DI 1
92
DI 2
53
44
93
DI 3
54
42
95
DI 5
64
96
DI 6
73
97
97
97
97
+24 V
DC
100 mA
>300 Ohm
98
99
DI 7
74
98
83
99
84
+
_
94
DI 4
63
41
PE
N/L+
L/L
_
>20 ms
_
+
_
Rel.2
8
3
R
L
83
R
L
RS 485
RxD/TxD(
_
)
RxD/TxD(+)
RxD/TxD(
_
)
RxD/TxD(+)
x16 x15
x16 x15
x16 x15
+
-
I
out
0...20 mA, 4...20 mA
+
-
+
-
U
out
1...5 V, 0...10 V
+
-
+
-
24 V
DC
, max. 25 mA
Loop power
supply
+
-
x15
x16
x15
x16
x15
x16
x11 x12 x13 x14
OC,max.
30V/100mA
Vout,max.
24V/100mA
115...230 V
50/60 Hz
AC
L
N
PE
24 V
0/50/60 Hz
AC/DC
+
_
PE
(~)
(~)
Power
L
N
+
_
(~)
(~)
+
-
+
-
-
+
x11 x12 x13 x14
x11 x12 x13 x14
x11 x12 x13 x14
x11 x12 x13 x14x11 x12 x13 x14
Pt100:
Pt500:
Pt1000:
Ni100:
Socket 1
Analogue/
digital*
board
R =
L
Further units
Cable
resistance
R =
L
Further units
Analogue inputs
Socket 3
Power
supply
board
CPU
board
Socket 2
Analogue/digital*/
multi-function
output board
*Relay connections:
Rel. 6...11 (term. 151...652) or rel. 12...17 (term. 751...C52) as with rel. 2...5 (term. 53...84)
Note
Sockets 1 and 2 can be fitted with either analogue input or digital output boards.
Socket 2 can be fitted with a multi-function output board.
Socket 3 is always fitted with the power supply board.
:
To PC: Cable with
9 pol. Sub-D connector
To modem: Cable with
9 pol. Sub-D connector
To modem: Cable with
25 pol. Sub-D connector
To PC: Cable with
25 pol. Sub-D
connector
Analogue outputs (can be preset in set-up)
0...20 mA, 4...20 mA
+/- 1 mA, +/-2 mA, +/- 4 mA, +/- 20 mA, +/- 40 mA
Internal shunt: 50 Ohm
-100...+500 °C or -50...+150 °C
-100...+500 °C
-100...+500 °C
-60...+180 °C
Only on stainless
steel bezel ATA-Flash
rear mounted
Cable
resistance
screened cable
752
852
952
A52
B52
C52
751
851
951
A51
B51
C51
Rel.12
Rel.13
Rel.14
Rel.15
Rel.16
Rel.17
+
-
+
-
+
-
+
-
+
-
+
-
+
-
+
-
E15
E16
F15
F16
G15
G16
H15
H16
A15
A16
B15
B16
C15
C16
D15
D16
Page view 13
1 2 ... 9 10 11 12 13 14 15 16 17 18 19 ... 97 98

Comments to this Manuals

No comments